A4-4
Operation
Checking
the
Adhesive Level
and
Filling
the Tank
Use
this procedure to check the adhesive level and to refill the tank if
necessary.
WARNING:
Risk of
personal injury. When the tank lid is
opened,
vapors may be released. Vent the application area or
wear a respirator for protection from vapors.
CAUTION:
Risk of
equipment damage. Exposing melted
adhesive
to air can accelerate the curing process, causing
char.
Refer
to
General Hot
Melt Material Processing lnstructions al
the beginning
of
this manual for adhesive material handling
guidelines.
1.
Open
the tank lid and check the adhesive level
2.
Refillthe tank before the adhesive level drops below
50%.
Use
a
metal
or plastic scoop to add unmelted adhesive to within 25 mm
(1 in.)
of
the top
of
the tank.
25 mm (1 in.)
50T"
1
2
3
4'130773
Fig. A
4-2
Filling the Tank
1.
Refill level
2.
Tank
filling
3.
Tank-fulllevel
3.
Close
the lid immediately after filling