Display Board Removal; Display Board Lnstallation B; System Restoration B; Replacing The Operator Panel - Nordson 3100V Series Customer Product Manual

Hot melt material applicator with 6:1 sp30 piston pump and vista'controller
Hide thumbs Also See for 3100V Series:
Table of Contents

Advertisement

B
2-36
Control
Replacing the Operator Panel
Display Board Removal
1.
lf
you have not already done so, complete Preparation for Removal.
2.
Remove
the power board and control
board.
Refer
to
Control
Board
Removal.
3.
Remove
the mounting hardware that secures the display board to the
control-end
frame and remove the display board.
NOTE: See Figure
B 2-14
for an exploded drawing
of
the control
assembly parts.
Display Board lnstal lation
1.
Bemove
the new board from its static-safe
container.
Handle
the
board by its edges
without touching any pins, wires, or circuitry.
2.
Align the
display board with the control-end frame and attach
it
with
the
mounting
hardware. Tighten allscrews 1o2.0-2.3 N.m (18-20
in.-lb).
3.
lnstall the
control board and power
board.
Go to
step
2in
Control
Board lnstallation.
System Restoration
1.
Reattach
the support strap to the control-end
frame.
Tighten
the
screw
lo2.0-2.3 N.m (18-20
in.-lb).
2.
Close and
secure the electrical
enclosure.
Refer
to
Opening
and
Closing the
Electrical Enclosure.
3.
lf
you replaced the control board, re-enter your customized system
settings, if
any.
Refer
to Sysfem Programming Procedures and
Records of System Seftings in lhe lnstallafion section.
Follow
this procedure
to
replace
the operator
panel.
As
an alternative,
you can save time by replacing the entire control
assembly.
Refer
to
Replacing the Control Assembly.
82EN-04-[3V-X-4XXVj-5