lnstallation
A
3-21
7.
Connect
the
output wires to
the
plug for
terminal
block TB2
from the
ship-with
kit.
Refer to Table A 3-3.
Table A
3-3
Output Contact
Connections
8.
Connect
the
plug to
TB2.
See
Figure A 3-12
for the location
otTB2.
9.
Go to
the
next
procedure,
Connecting
ElectricalSeruice.
Output Contact as
Labeled on Power
Board
Behavior of Contact
TB2
Positions
(see Note A)
Unit Power Off
Unit Power
On
Warning
Contact
(System Warning)
Fault
Contact
(System
Fault)
Ready
Contact
(System
Ready)
Open
Open
Open
Closed
(no warning)
Closed
(no fault)
Open
(unit
not
ready)
Open
(warning exists)
Open
(fault exists)
Closed
(unit ready)
1
,
2
3,4
5,6
NOTE A: The
output
contacts are
not polarity
sensitive. lt does
not matter which
wire
is
inserted
into a position.
@00
Nordson
Corporation
All
ights
reserved
41-3000y
lssued
5/00
A3EN-04-[3V-X-4XXVj-1 3