Nordson 3100V Series Customer Product Manual page 146

Hot melt material applicator with 6:1 sp30 piston pump and vista'controller
Hide thumbs Also See for 3100V Series:
Table of Contents

Advertisement

Operation
A 4-9
3.
Check
the Multipurpose display to determine the warning or fault
code
of
the warning or fault currently displayed; then refer to
Table A 4
-3 and either Table
A
4-4
or A
4-5 to determine the meaning
of
the warning or fault code.
Multipurpose Display
zone number
-
code
Actua! Temperature Display
heaters on
time when
faulVwarning occurred.
For
example,
3-2
in
the multipurpose display would indicate that
hose
2 has an open RTD and the number in the temperataure display
would indicate how long the heaters had been on when the warning
or
fault occurred.
Table
A 4-3
Zone Codes for Warning
and Fault Logs
Table A
4-4
Meaning of Warning Codes
Table A
4-5
Meaning
of Fault Codes
#
Zone
#
Zone
#
Zone
0
1
2
3
4
Tank
Grid
Hose
1
Hose
2
Hose
3
5
6
7
I
I
Hose 4
Hose
5
Hose
6
Gun
1
Gun
2
10
11
12
13
Gun
3
Gun
4
Gun
5
Gun
6
Warning Code
Meaning of Warning Code
0
1
2
3
4
5
6
No
fault has occurred.
Not used.
An RTD is open.
An RTD
is
shorted.
A zone
temperature is out of band.
Not used.
Not used.
Fault Code
Meaning of Fault Code
0
1
2
o
4
5
6
No
fault has occurred.
A
zone is below the setpoint temperature.
An RTD is open.
An RTD is shorted.
A
zone
is
overtemperature.
The
control board is
bad.
A brownout has occurred.
e000
Nordson Corporation
All righls resewed
41-3000v
lssued 5/00
A4EN-06-[3V-A-AAXVI-1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

3400v series3500v series3700v series

Table of Contents