Series 3000V lnput/Output Board
5.
Troubleshooting
For
wiring information, refer to
the
Wiring Diagrams section
Problem
Possible Cause
Corrective Action
1
lnputs not being
recognized
Loose connection
lnput voltage not sufficient
Defective l/O board
Check the
tightness of connections at
the l/O board and at the remote devices.
Tighten any loose connections.
Make sure the
voltage across the
appropriate
terminals on X1
or
TB10
is
12-24VDC.
Replace
the l/O
board.
Reter
lo l/O
Board Replacement.
2.
Outputs not working
Loose
connection
Defective l/O board
Check
the tightness
of
the
connections
at
the l/O
board and at
the remote
devices. Tighten any
loose connections.
Replace
the l/O
board.
Refer
to
l/O Board Replacement.