Programmingtempehature Controls - Nordson 3100V Series Customer Product Manual

Hot melt material applicator with 6:1 sp30 piston pump and vista'controller
Hide thumbs Also See for 3100V Series:
Table of Contents

Advertisement

lnstallation
A 3-33
P
rogram mi
ng
TEM PE
RATU
R
E
Controls
From
the operator panel you can control each
of
the system's heated
components at
a
temperature specific to your
needs.
You
can program
individual setpoints for the
tank, each hose, each gun, and, on Series
3900Vunits, the
grid.
For
programming purposes, each heated system
component is referred to as a zone.
ln addition
to being able to heat each zone individually, you can assign
two different temperature settings
to each active
zone;
a setting for
the
setpoint (operating) temperature and one for the standby temperature.
Table A
3-6
Types
of
Temperature Settings
lf
you do not enter standby temperatures, the standby default of OFF will
remain in effect for each
zone.
lf
you place the system
in
the standby
mode, the zones will
coolto
room
temperature (while the HEATERS light
remains
on).
lf
you make the standby temperatures equal to the
setpoints, pressing the STANDBY key will have
no
effect on the
temperatures, but
it
willturn the
READY
light off and disable the pump.
NOTE: The
default setting
for
allzones
is
OFF (less than 38
"C or
100
"F).
To
turn
a
zone
on, set the setpoint temperature to
38
"C (100
'F)
or
higher.
Setting
Description
Setpoint Temperature
Standby Temperature
Desired
temperature of
a
zone during
normal operation.
Temperature
to which
a
zone will
be
reduced when
the system is in the standby
mode.
@
2000 Nordson Corpoialion
All
dghts
reserved
41-3000y
lssued
5/O0
A3
EN-04-[3V-X-4XXVI-1 3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

3400v series3500v series3700v series

Table of Contents