B
2-22
Control
Checking
the 480 Vac
Distri bution Board Harnesses
and the Transformer
@ontd.)
Checking a Heater or Heater
Circuit
7.
Repeat the
voltage measurement at pins 6 and
B
of
the harness
connected to X1D.
Voltage
does not measure
207-253 VAC: defective harness or
transformer.
Replace
the
harness. lf
replacing
the harness does
not solve
the problem, replace the transformer.
Voltage
measures
207-253 VAC: normal indication.
Go to
the
next step.
8.
Measure the
voltage at pins
2
and
4
of
the harness connected to X3D
on the
480 VAC distribution board and
at
TBI
positions
A and
B on
the power board.
Voltage
does not measure 230
VAC: defective harness or
transformer.
Replace
the
harness. lf
replacing
the harness does
not solve
the problem, replace the transformer.
Voltage measures 230
VAC:
normal
indication.
Return to
the Unit
Not
Powering
On
troubleshooting table.
Follow
this procedure to check a heater or heater circuit.
WARNING:
Risk of
equipment damage, personal injury, or
death. Disconnect and lock
out
electrical power to the unit,
including inpuVoutput (l/O) lines.
1.
Place
the unit's POWER switch in the off position, disconnect and
lock out
electrical power to the unit
at
the branch circuit disconnect
switch, and disconnect and lock out electrical power supplied through
any l/O wiring.
2.
Open
the electrical
enclosure.
Refer
to
Opening
and Closing the
Electrical Enclosure.
3.
Check
the heater by measuring its resistance
at
the heater connector
harness
pins.
Refer to Table B
2-5 to determine which board the
zone's heater connectors are located
on.
See Figure
B
2-4 for
the
location of
the connectors on
the boards.
Remove
the harness from
the
connector and measure
the resistance
across
the harness pins
identified
in
Table
B
2-5.
Resistance reading of zero
(0):
heater short
circuit.
Check
for a
short in the heater circuit and repair the short.
lnfinite resistance
reading: open
heater
circuit or
heater.
Go
to
the next step.
a
a
a
a
a
a
82
EN-04-[3V-X-4XXyl-s