Hydraulics
B
1-9
Pump
Air
Section Check
1.
Reduce
the pump air pressure to
0.
2.
Remove
the pump cover.
3.
Make sure
the READY light is lit and the pump
is
turned
on.
4.
See Figure B
1-4.
Slowly increase pump
air pressure and check
for
leaks
.
at
the actuator's top or bottom exhaust port
(1)
.
at the
top
of
the hydraulic shaft
(2)
.
between
the air cylinder head and the air cylinder or between the
air cylinder and
the pump mount
(3)
.
between
the actuator and air cylinder
(4)
3
1
4
2
413003S
Fig.
B
1-4
Checking
for
Pump Air
Section
Leaks
1.
Exhaust ports
2.
Top of hydraulic shaft
3.
Between air
cylinder
head and
air
cylinder or
between
air
cylinder and
pump
mount
4.
Between
actuator
and
air
cylinder
@
2000