Control System On 480 Vac Three-Phase Units B - Nordson 3100V Series Customer Product Manual

Hot melt material applicator with 6:1 sp30 piston pump and vista'controller
Hide thumbs Also See for 3100V Series:
Table of Contents

Advertisement

B
2-4
Control
Control
System on 480 Vac
Three-Phase Units
3.
TroubleshootingTables
Your hot melt unit
operates on 480 VAC three-phase
(32)
incoming
power, which you
connected to
a
terminal block on the
480 VAC
distribution
board.
A 480 VAC/230 VAC
1O isolation
transformer provides 230 VAC power to the control assembly. The tank
heaters
operate on 480 VAC
power.
A
solid-state relay controls the
heater power to the tank heaters through the control
board.
Fuses
F1,
F2,
and F3
on
the 480 VAC distribution board provide protection for the
480 VAC power section, which includes the transformer and the tank
heaters.
Gun
and hose heaters are powered by the power board and
operate at 230
VAC. The tank
heater
circuit
on
the power board is not
used on 480 VAC units.
The following troubleshooting tables describe the kinds of control system
problems
you may encounter and provide corrective actions for handling
those
problems. When
necessary,
the tables refer to more detailed
troubleshooting procedures.
Refer to
the appropriate troubleshooting table for the type of problem you
are experiencing:
.
lnternal, Hose, or Gun
Zone
Not
Heating
.
Settings Changed
or
Lost
.
Unit
Not
Powering On
o
Control System lndicating
a
Warning
-
Out-of-Band Warning
-
UndenTemperature (UT) Warning
.
ControlSystem lndicating a Fault
-
Over-Temperature (OT)
Fault
-
Resistance Temperature
Detector (RTD) Fault
-
Fault-Code
Fault
(F1-F7)
82EN-04-[3V-X-4XXVI-s
4't-3000v
lssued 5/00
@
2000
Nordson
Corporation
All
rights reserved