Defining Runtime Settings

SETUP TOOL
Please select how to load a configuration file
LOAD FROM USB/COMPUTER
USE PREVIOUS FILE
CREATE NEW
RUNTIME SETTINGS
ZONE TEMPERATURE
Part 1129255_01
The following sections detail the common operator tasks:
S
Temperature settings
S
Pressure settings

Defining Temperature Runtime Setting

There are two types of heated zones:
S
Internal Zones: Tank and Manifold
S
External Zones: Connected hoses and applicators
NOTES:
S
By default, internal zones are enabled, and all external zones are
disabled.
S
Internal zones (tank and manifold) cannot be disabled. You can only
change their set point temperatures.
S
Although there are two internal zones (tank and manifold), changing one
internal zone automatically changes the other. You cannot have two
different internal zone set point temperatures.
Enabling/Disabling and Changing Zone Set Point
Temperatures
1. Log into your BBconn Cloud account, then do the following::
S
Select SETUP TOOL - create or load a .NOR file
S
Select SETUP TOOL | RUNTIME SETTINGS | ZONE
TEMPERATURE.
2. Do the following to continue:
S
Press the
to toggle (enable or disable) the zone.
S
To change the set point temperature, select which zone you want to
change and enter the temperature set point your want.
S
Enter a Global Set Point temperature to make all zones, (enabled or
disabled) the same set point temperature.
Zone
Internal Zones
(Tank/Manifold)
External Zones
3. When done, press SAVE.
NOTE:
S
You can change the default external zone names using either a PLC or
BBconn Cloud. Refer Modifying External Zone Names for more
information.
Default
Minimum
177_ C
40_ C
_
(351
F)
(100_ F)
_
177_ C
40
C
(351_ F)
(100_ F)
Maximum
204_ C
(400_ F)
232_ C
(450_ F)
E 2020 Nordson Corporation