Switching The Master Heater And Pump Controls On/Off - Nordson ProBlue Flex Manual

Adhesive melter using the oled user interface
Hide thumbs Also See for ProBlue Flex:
Table of Contents

Advertisement

24
OLED User Interface

Switching the Master Heater and Pump Controls On/Off

System Status
Master Pump Control
Part 1128351_02
When you power-up the melter, by default, the Master Heaters and Pump
controls are switched Off. You must manually switch them On.
S
To toggle the Master Heater control On, Press the
button. The LED illuminates. Press the master control button again to
switch it Off.
However, you can make use of the Heaters on Upon Startup (System
Settings | Global Settings) to change this behavior.
S
To toggle the Master Pump control On, press
flashes.
S
If AutoPump is enabled, then the pump button will flash, indicating that
the Master Pump control will be toggled On as soon as system
temperature ready is achieved. If you press the Master Pump Control
button again, AutoPump becomes disabled, although only for this one
time. When the system Temperature Ready is achieved, the Master
pump Control remains Off. In this case, pushing the Master Pump Control
button again will switch the Master Pump Control On, since system
temperature ready has already been achieved.
S
If you press the Master Pump control button with AutoPump disabled and
before the system is not at Temperature Ready, AutoPump is
momentarily Enabled and the Pump button flashes.
Master Heater Control
master control
The Pump LED
E 2020 Nordson Corporation

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents