Hitachi H8/3664 Hardware Manual page 100

Table of Contents

Advertisement

Bit 5—Direct Transfer on Flag (DTON): This bit designates whether to make direct transitions
between the active and subactive modes when a SLEEP instruction is executed. The mode to
which the transition is made after the SLEEP instruction is executed depends on a combination of
this and other control bits.
Bit 5: DTON
0
1
Bits 4 to 2—Active Mode Clock Select (MA2 to MA0): These bits select the operating clock
frequency in the active and sleep modes. The operating clock frequency changes to the set
frequency after the SLEEP instruction is executed.
Bit 4: MA2
Bit 3: MA1
0
*
1
0
1
Note: * Don't care
Bits 1 and 0— Subactive Mode Clock Select (SA1, SA0): These bits select the operating clock
frequency in the subactive and subsleep modes. The operating clock frequency changes to the set
frequency after the SLEEP instruction is executed.
Bit 1: SA1
0
1
Note: * Don't care
84
Description
When a SLEEP instruction is executed, a transition is made to standby mode,
sleep mode, or subsleep mode.
When a SLEEP instruction is executed, a direct transition is made to active
mode if LSON = 0, or to subactive mode if LSON = 1.
Bit 2: MA0
*
0
1
0
1
Bit 0: SA0
0
1
*
Description
ø
osc
ø
/8
osc
ø
/16
osc
ø
/32
osc
ø
/64
osc
Description
ø
/8
W
ø
/4
W
ø
/2
W
(Initial value)
(Initial value)
(Initial value)

Advertisement

Table of Contents
loading

Table of Contents