Programmer Mode Operation - Hitachi H8/3664 Hardware Manual

Table of Contents

Advertisement

7.10.2

Programmer Mode Operation

Table 7.12 shows how the different operating modes are set when using programmer mode, and
table 7.13 lists the commands used in programmer mode. Details of each mode are given below.
• Memory Read Mode
Memory read mode supports byte reads.
• Auto-Program Mode
Auto-program mode supports programming of 128 bytes at a time. Status polling is used to
confirm the end of auto-programming.
• Auto-Erase Mode
Auto-erase mode supports automatic erasing of the entire flash memory. Status polling is used
to confirm the end of auto-programming.
• Status Read Mode
Status polling is used for auto-programming and auto-erasing, and normal termination can be
confirmed by reading the I/O6 signal. In status read mode, error information is output if an
error occurs.
Table 7.12 Settings for Various Operating Modes In Programmer Mode
Mode
Read
Output disable
Command write
Chip disable
Notes: Chip disable is not a standby state; internally, it is an operation state.
*Ain indicates that there is also address input in auto-program mode.
CE
OE
L
L
L
H
L
H
H
X
Pin Names
WE
I/O7– I/O0
H
Data output
H
Hi-z
L
Data input
X
Hi-z
A18–A0
Ain
X
*Ain
X
125