12. Measure resistance between g r o u n d w i r e (A) and
Y capacitor t e r m i n a l s + (B), — (C) individually.
NOTE: Use 250 V range of the insulation resistance
tester.
Is there 350 k& or
higher?
Y E S — G o to step 13.
NO—Replace the Y capacitor (see page 12-142),
then go to step 49.
13. Remove the busbar (A) and w i r e (B) f r o m the high
voltage contactor.
14. Remove the junction board terminals (C).
15. Measure resistance between body g r o u n d and high
voltage contactor terminals + (D), — (E)
individually.
Is there 350 kQ or
higher?
Y E S — G o t o step 16.
NO—Replace the high voltage contactor (see page
12-142), then go to step 49.
16. Disconnect the wires (A) f r o m the bypass contactor
(B).
C
D
17. Measure resistance between body g r o u n d and
bypass contactor terminals No. 1 (C), No. 2 (D)
individually.
Is there 350 k& or
higher?
Y E S — G o to step 18.
NO—Replace the bypass contactor (see page
12-142), then go to step 49.
18. Measure resistance between body g r o u n d and wire
Is there 350 kQ or
higher?
Y E S — G o t o step 19.
NO—Replace the bypass contactor (see page
12-142), then go to step 49.
(cont'd)