Automatic Transmission
S y s t e m D e s c r i p t i o n ( c o n t ' d )
Power Flow (cont'd)
R Position
• Hydraulic pressure is applied t o the servo valve t o engage the reverse selector w i t h the countershaft reverse gear
w h i l e the shift lever in the R position.
• Hydraulic pressure is applied to the 5th clutch, then the 5th clutch engages the mainshaft reverse gear w i t h the
mainshaft.
• The mainshaft reverse gear drives the countershaft reverse gear via the reverse idler gear.
• The countershaft reverse gear drives the countershaft via the reverse selector w h i c h drives the reverse selector hub.
• The rotation direction of the countershaft is changed by the reverse idler gear.
• Power is transmitted to the final drive gear, w h i c h in turn drives the final driven gear.