Safety application examples
Example 1: Diagnostics concept > Functional description of safety functions
6
Second cartonning machine, guarded by an
electro-sensitive protective equipment, ESPE. In
this case, it is a light curtain.
7
Palletizing function, guarded by safety mats. This
functionality could be coupled to the ESPE safety
function.
In addition, every station is equipped with an emergency stop.

7.2 Example 1: Diagnostics concept

This example shows the usage of the diagnostic concept, with a daisy chain from the FB parameters Acti-
vate and Ready (with perhaps a pre-evaluation of hardware errors), and a coupling to an HMI screen with
error IDs and messages through the functional application. For clarity sake of the safety function, the other
Ä Chapter 7.3 "Example 2: Muting" on page 430 and Ä Chapter 7.4 "Example 3: Two-hand con-
examples (
trol" on page 437) will not show the diagnostic connections.
The safety functionality is to stop a drive in accordance with stop category 1 of IEC 60204-1 initiated by an
Emergency stop or by interrupting the light curtain. The equivalent monitoring of the 2 connectors of the
emergency switch is done in the safety application.
In this example, both options of input evaluation are shown:
n
via intelligent safety input
n
via the equivalent function block.

7.2.1 Functional description of safety functions

This example uses the following safety functions:
Issuing the emergency stop (via SF_EmergencyStop) or interrupting the light beam in the light curtain
n
(via SF_ESPE) stops the drive in accordance with stop category 1.
n
The stop of the electrical drive within a predefined time is monitored (via SF_SafeStop1).
n
The Safe Status of the drive is indicated by the S_Stopped variable, connected to the functional applica-
tion.
n
If the stop is performed by the Emergency Switch, a manual reset is required (via SF_EmergencyStop).
n
If a monitoring time violation is detected (via SF_SafeStop1), manual error acknowledge is required to
allow a reset.
The 2 channel connectors of the emergency stop are monitored. An error is detected when both inputs
n
do not have the same status once the discrepancy time has elapsed (via SF_EQUIVALENT).
n
The functional stop in this example is performed as a safe stop issued from the functional application. A
restart interlock for this stop is not necessary.
426
8
Foil wrapping station of the palletized products,
as well as exit of the production line. This area is
safeguarded by several combined light beams,
coupled to the ESPE safety function.