ABB AC500-S Safety User Manual page 328

Safety programmable logic controllers system
Hide thumbs Also See for AC500-S:
Table of Contents

Advertisement

Configuration and programming
AC500-S Libraries > SafetyBlocks_PLCopen_AC500_v22.lib
DiagCode
State Name
C004
Reset Error 4
C005
Reset Error 5
C006
Reset Error 6
C007
Reset Error 7
328
State Description and Output Setting
Static Reset condition detected in state C020.
Ready = TRUE
S_OSSD_Out = FALSE
S_TestOut = TRUE
TestPossible = FALSE
TestExecuted = FALSE
Error = TRUE
Static Reset condition detected in state 8006.
Ready = TRUE
S_OSSD_Out = FALSE
S_TestOut = TRUE
TestPossible = FALSE
TestExecuted = FALSE
Error = TRUE
Static Reset condition detected in state C000.
Ready = TRUE
S_OSSD_Out = FALSE
S_TestOut = TRUE
TestPossible = FALSE
TestExecuted = FALSE
Error = TRUE
Static Reset condition detected in state 8013.
Ready = TRUE
S_OSSD_Out = FALSE
S_TestOut = TRUE
TestPossible = FALSE
TestExecuted = TRUE
Error = TRUE
AC500-S
30.03.2017

Hide quick links:

Advertisement

Table of Contents
loading