DiagCode
State Name
8001
Init
8002
Operation
Mode
8012
Wait for Con-
firmation
OpMode
8003
Wait for Con-
firmation
8005
Wait for
OpMode
378
State Description and Output Setting
State after Activate is set to TRUE or after a rising trigger at Reset.
Ready = TRUE
S_SafetyActive = FALSE
S_SafetyRequest = FALSE
Error = FALSE
Operation mode without Acknowledge of safe mode
Ready = TRUE
S_SafetyActive = FALSE
S_SafetyRequest = TRUE
Error = FALSE
Operation mode with Acknowledge of safe mode
Ready = TRUE
S_SafetyActive = FALSE
S_SafetyRequest = TRUE
Error = FALSE
Waiting for confirmation from the drive (system interface).
Ready = TRUE
S_SafetyActive = FALSE
S_SafetyRequest = FALSE
Error = FALSE
Error was cleared. However S_OpMode must be set to TRUE before the
FB can be initialized.
Ready = TRUE
S_SafetyActive = FALSE
S_SafetyRequest = FALSE
Error = FALSE