ABB AC500-S Safety User Manual page 304

Safety programmable logic controllers system
Hide thumbs Also See for AC500-S:
Table of Contents

Advertisement

Configuration and programming
AC500-S Libraries > SafetyBlocks_PLCopen_AC500_v22.lib
Function Block-Specific Error and Status Codes
Table 52: FB-specific error codes
DiagCode
State Name
C001
Reset Error
C011
Discrepancy-
time Error 1
C012
Discrepancy-
time Error 2
Table 53: FB-specific status codes (no error):
DiagCode
State Name
0000
Idle
8000
Normal
8001
Init
8002
Open Guard
Request
304
State Description and Output Setting
Static reset detected in state 8003.
Ready = TRUE
S_GuardMonitoring = FALSE
Error = TRUE
DiscrepancyTime elapsed in state 8004.
Ready = TRUE
S_GuardMonitoring = FALSE
Error = TRUE
DiscrepancyTime elapsed in state 8014.
Ready = TRUE
S_GuardMonitoring = FALSE
Error = TRUE
State Description and Output Setting
The function block is not active (initial state).
Ready = FALSE
S_GuardMonitoring = FALSE
Error = FALSE
Safety guard closed and Safe state acknowledged.
Ready = TRUE
S_GuardMonitoring = TRUE
Error = FALSE
Function block has been activated.
Ready = TRUE
S_GuardMonitoring = FALSE
Error = FALSE
Complete switching sequence required.
Ready = TRUE
S_GuardMonitoring = FALSE
Error = FALSE
AC500-S
30.03.2017

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents