Table 51: FB Name: SF_GuardMonitoring
Name
Data Type
VAR_INPUT
Activate
BOOL
S_GuardSwitch1
BOOL
S_GuardSwitch2
BOOL
DiscrepancyTime
TIME
S_StartReset
BOOL
S_AutoReset
BOOL
Reset
BOOL
VAR_OUTPUT
Ready
BOOL
S_GuardMoni-
BOOL
toring
Error
BOOL
DiagCode
WORD
30.03.2017
AC500-S Libraries > SafetyBlocks_PLCopen_AC500_v22.lib
Initial Value
Description, Parameter Values
FALSE
Ä Table 31 "General Input Parameters"
on page 266
FALSE
Variable.
Guard switch 1 input.
FALSE: Guard is open.
TRUE: Guard is closed.
FALSE
Variable.
Guard switch 2 input.
FALSE: Guard is open.
TRUE: Guard is closed.
T#0ms
Constant.
Configures the monitored synchronous time
between S_GuardSwitch1 and S_GuardSwitch2.
Ä Table 31 "General Input Parameters"
FALSE
on page 266 – Only Constant
Ä Table 31 "General Input Parameters"
FALSE
on page 266 – Only Constant
Ä Table 31 "General Input Parameters"
FALSE
on page 266
FALSE
Ä Table 32 "General Output Parameters"
on page 267
FALSE
Output indicating the status of the guard.
FALSE: Guard is not active.
TRUE: both S_GuardSwitches are TRUE, no
error and acknowledgment. Guard is active.
Ä Table 32 "General Output Parameters"
FALSE
on page 267
Ä Table 32 "General Output Parameters"
16#0000
on page 267
AC500-S
Configuration and programming
301