ABB AC500-S Safety User Manual page 338

Safety programmable logic controllers system
Hide thumbs Also See for AC500-S:
Table of Contents

Advertisement

Configuration and programming
AC500-S Libraries > SafetyBlocks_PLCopen_AC500_v22.lib
Example for SF_MutingSeq in forward direction with four sensors
1
If muting sensor MutingSwitch12 (MS_12) is activated by the product after MutingSwitch11 (MS_11), the
muting mode is activated.
2
Muting mode remains active as long as MutingSwitch11 (MS_11) and MutingSwitch12 (MS_12) are activated
by the product. The product may pass through the light curtain without causing a machine stop.
3
Before muting sensors MutingSwitch11 (MS_11) and MutingSwitch12 (MS_12) are disabled, muting sensors
MutingSwitch21 (MS_21) and MutingSwitch22 (MS_22) must be activated. This ensures that muting mode
remains active.
4
Muting mode is terminated if only muting sensor MutingSwitch22 (MS_22) is activated by the product.
Muting Conditions
Forward Direction
Muting condition 1 (to 8011) (MS_11 is the first entry switch actuated). Start timer MaxMutingTime: