ABB AC500-S Safety User Manual page 310

Safety programmable logic controllers system
Hide thumbs Also See for AC500-S:
Table of Contents

Advertisement

Configuration and programming
AC500-S Libraries > SafetyBlocks_PLCopen_AC500_v22.lib
DiagCode
State Name
8005
Button 1 Actu-
ated
8006
Button 2 Actu-
ated
8007
Button 2
Released
8008
Button 1
Released
8009
Locked Off
8019
Locked On
310
State Description and Output Setting
Only Button 1 is actuated.
Ready = TRUE
Error = FALSE
S_TwoHandOut = FALSE
Only Button 2 is actuated.
Ready = TRUE
Error = FALSE
S_TwoHandOut = FALSE
The safety related output was enabled and is disabled again.
FALSE at both S_Button1 and S_Button2 was not achieved after disabling
the safety related output.
In this state, S_Button1 is TRUE and S_Button2 is FALSE after disabling
the safety related output.
Ready = TRUE
Error = FALSE
S_TwoHandOut = FALSE
The safety related output was enabled and is disabled again.
FALSE at both S_Button1 and S_Button2 was not achieved after disabling
the safety related output.
In this state, S_Button1 is FALSE and S_Button2 is TRUE after disabling
the safety related output.
Ready = TRUE
Error = FALSE
S_TwoHandOut = FALSE
The safety related output was enabled and is disabled again.
FALSE at both S_Button1 and S_Button2 was not achieved after disabling
the safety related output.
In this state, S_Button1 is TRUE and S_Button2 is TRUE after disabling
the safety related output.
Ready = TRUE
Error = FALSE
S_TwoHandOut = FALSE
Incorrect actuation of the buttons. Waiting for release of both buttons.
Ready = TRUE
Error = FALSE
S_TwoHandOut = FALSE