Table 48: FB Name: SF_ESPE
Name
Data Type
VAR_INPUT
Activate
BOOL
S_ESPE_In
BOOL
S_StartReset
BOOL
S_AutoReset
BOOL
Reset
BOOL
VAR_OUTPUT
Ready
BOOL
S_ESPE_Out
BOOL
Error
BOOL
DiagCode
WORD
30.03.2017
AC500-S Libraries > SafetyBlocks_PLCopen_AC500_v22.lib
Initial Value
Description, Parameter Values
FALSE
Ä Table 31 "General Input Parameters"
on page 266
FALSE
Safety demand input.
Variable.
FALSE: ESPE actuated, demand for safety-
related response.
TRUE: ESPE not actuated, no demand for safety-
related response.
Safety control system must be able to detect a
very short interruption of the sensor (which is
specified in 61496-1: minimum 80 ms), when the
ESPE is used in applications as a trip device
FALSE
Ä Table 31 "General Input Parameters"
on page 266
FALSE
Ä Table 31 "General Input Parameters"
on page 266
FALSE
Ä Table 31 "General Input Parameters"
on page 266
Ä Table 32 "General Output Parameters"
FALSE
on page 267
FALSE
Output for the safety-related response.
FALSE: Safety output disabled.
Demand for safety-related response (e.g., reset
required or internal errors active).
TRUE: Safety output enabled. No demand for
safety-related response.
FALSE
Ä Table 32 "General Output Parameters"
on page 267
16#0000
Ä Table 32 "General Output Parameters"
on page 267