ABB AC500-S Safety User Manual page 346

Safety programmable logic controllers system
Hide thumbs Also See for AC500-S:
Table of Contents

Advertisement

Configuration and programming
AC500-S Libraries > SafetyBlocks_PLCopen_AC500_v22.lib
Table 69: FB Name: SF_MutingPar
Name
Data Type
VAR_INPUT
Activate
BOOL
S_AOPD_In
BOOL
MutingSwitch11
BOOL
MutingSwitch12
BOOL
MutingSwitch21
BOOL
MutingSwitch22
BOOL
S_MutingLamp
BOOL
MutingEnable
BOOL
S_StartReset
BOOL
346
Initial Value
Description, Parameter Values
FALSE
Ä Table 31 "General Input Parameters"
on page 266
FALSE
Variable.
OSSD signal from AOPD.
FALSE: Protection field interrupted.
TRUE: Protection field not interrupted.
FALSE
Variable.
Status of Muting sensor 11.
FALSE: Muting sensor 11 not actuated.
TRUE: Workpiece actuates muting sensor 11.
FALSE
Variable.
Status of Muting sensor 12.
FALSE: Muting sensor 12 not actuated.
TRUE: Workpiece actuates muting sensor 12.
FALSE
Variable.
Status of Muting sensor 21.
FALSE: Muting sensor 21 not actuated.
TRUE: Workpiece actuates muting sensor 21.
FALSE
Variable.
Status of Muting sensor 22.
FALSE: Muting sensor 22 not actuated.
TRUE: Workpiece actuates muting sensor 22.
FALSE
Variable or constant.
Indicates operation of the muting lamp.
FALSE: Muting lamp failure.
TRUE: Muting lamp no failure.
FALSE
Variable or constant.
Command by the control system that enables the
start of the muting function when needed by the
machine cycle. After the start of the muting func-
tion, this signal can be switched off.
FALSE: Muting not enabled
TRUE: Start of Muting function enabled
Ä Table 31 "General Input Parameters"
FALSE
on page 266
AC500-S
30.03.2017