Configuration Guide - Reliability
cpos-trunk 0
#
controller Cpos2/0/0
undo shutdown
aps group 1
aps protect
aps mode one-plus-one unidirection
cpos-trunk 0
#
interface Cpos-Trunk0
undo shutdown
e1 1 unframed
e1 2 unframed
#
interface Global-Mp-Group0
undo shutdown
#
interface Trunk-Serial0/1:0
undo shutdown
link-protocol ppp
ppp mp-global global-mp-group 0
#
interface Trunk-Serial0/2:0
undo shutdown
link-protocol ppp
ppp mp-global global-mp-group 0
#
return
3.4.3 Example for Associating PW Redundancy with E-APS
Working in 1:1 Mode
This section provides a configuration example for associating PW redundancy with E-APS
working in 1:1 mode. A networking diagram is provided to demonstrate the configuration
procedure. The configuration example includes networking requirements, configuration
roadmap, configuration procedure, and configuration files.
Networking Requirements
As shown in
occurs on the network side, the switchover of TE groups rather than PWs is performed. When
a fault occurs on the AC side, the switchover between the working interface and the protection
interface is performed on the AC side according to APS. This leads to the switchover of PWs
and thus avoids the loss of the network data.
Issue 02 (2011-09-10)
Figure
3-4, PE1 is dual-homed to PE2 and PE3 through two PWs. When a fault
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
3 APS Configuration