Figure 1-3 Networking diagram of MPLS OAM protecting switchover
PE1
As shown in
forming a protection group. A TE tunnel is created between PE2 and PE1 through P1 as a reverse
channel, advertising a failure to ingress PE1.
BFD
BFD and OAM are similar because both of them define a set of mechanisms including detection,
failure report, and switchover. For BFD and OAM, the detection is carried out by sending fast
detection packets through a preset path to detect the link status. If the detection packets cannot
pass through the link, the packets are dropped. To avoid the jitters, the number of detection
packets is specified. When the number of the lost detection packets reaches the set value, the
link is considered as interrupted.
BFD is a bidirectional detection mechanism, and its detection packets are sent bidirectionally.
If one end does not receive the detection packets within a specified period, the end assumes that
the link is interrupted and reports to related modules to perform switchover.
Issue 02 (2011-09-10)
MPLS TE
Tunnel
Figure
1-3, two TE tunnels are created between the ingress PE1 and egress PE2,
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
P1
P2
P3
1 Reliability Overview
PE2