Optional) Restarting The Smb; Checking The Configuration - Huawei NetEngine80E Configuration Manual - Reliability

Hide thumbs Also See for NetEngine80E:
Table of Contents

Advertisement

HUAWEI NetEngine80E/40E Router
Configuration Guide - Reliability
The system view is displayed.
Step 2 Run:
slave switchover
The force AMB/SMB switchover is enabled.
After the configuration, you can run the
SMB switchover manually.
By default, the force AMB/SMB switchover is enabled.
To disable the force AMB/SMB switchover, run the
----End

6.2.5 (Optional) Restarting the SMB

After the software version on the SMB is upgraded, you can restart the SMB.
Context
During the on-line software upgrade, the SMB software is upgraded when the AMB works
normally. Then, the SMB must be restarted. After the SMB is ready, the AMB/SMB switchover
can be performed.
Do as follows on the GR Restarter:
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
slave restart
The SMB is restarted.
----End

6.2.6 Checking the Configuration

By viewing the status of the AMB and SMB, you can check whether the configurations are
successful.
Prerequisite
The configurations of the system-level GR function are complete.
Procedure
Step 1 Run the
----End
Issue 02 (2011-09-10)
enable
display switchover state
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
slave switchover
command to perform the force AMB/
slave switchover
command to check the status of AMB and SMB.
6 GR Configuration
disable command.