system-view
The system view is displayed.
Step 2 Run:
slave default
The default slot number for the SMB is configured.
----End
6.2.3 Enabling the Automatic Synchronization of the AMB/SMB
Configuration
You can enable the SMB to automatically synchronize configurations with the AMB when the
AMB is writing the configurations.
Context
Do as follows on the GR Restarter:
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
slave auto-update config
The automatic synchronization of the AMB/SMB configuration is enabled.
If the
updates the configuration on the SMB to synchronize the configurations on the AMB and the
SMB.
By default, the automatic synchronization of configuration data between AMB and SMB is
enabled.
To disable the automatic synchronization of configuration data between AMB and SMB, run
the
----End

6.2.4 Enabling the Force AMB/SMB Switchover

The AMB and SMB can be switched to each other after the AMB/SMB switchover is enabled.
Context
Do as follows on the GR Restarter:
Procedure
Step 1 Run:
system-view
Issue 02 (2011-09-10)
slot-id
save
command is run on the AMB to save the configuration, the system automatically
undo slave auto-update config
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
command.