Step 2 Run:
bfd
BFD is enabled globally, and the global BFD view is displayed.
Step 3 Run:
snmp-agent bfd trap-interval
The interval at which trap messages are sent is set.
By default, the interval at which trap messages are sent is 120 seconds.
----End

5.14.3 Checking the Configuration

By viewing the interval at which trap messages are sent, you can check whether the
configurations are successful.
Prerequisite
The configurations of the interval at which trap messages are sent are complete.
Procedure
l
----End
Example
Run the
the interval at which trap messages are sent is 300 seconds.
<HUAWEI> display current-configuration configuration bfd
#
bfd
snmp-agent bfd trap-interval 300
#
return

5.15 Maintaining BFD

This section describes how to maintain BFD by deleting BFD statistics, and monitoring BFD
operation.

5.15.1 Clearing BFD Statistics

Deleting previous BFD statistics is recommended before BFD statistics within a specified period
of time are collected.
Issue 02 (2011-09-10)
Run the
display current-configuration
configuration of the BFD trap function.
display current-configuration
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
interval
configuration bfd command to view the
configuration bfd command, and you can view that
5 BFD Configuration