Checking The Configuration - Huawei NetEngine80E Configuration Manual - Reliability

Hide thumbs Also See for NetEngine80E:
Table of Contents

Advertisement

HUAWEI NetEngine80E/40E Router
Configuration Guide - Reliability
Do as follows on the devices at one end or both ends of the link:
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
interface
The interface view of an interface at one end of the link is displayed.
Step 3 Run:
efm error-frame-second period
The period for detecting errored frame seconds on the interface is set.
By default, the period for detecting errored frame seconds on an interface is 60 seconds.
Step 4 Run:
efm error-frame-second threshold
The threshold for detecting errored frame seconds on the interface is set.
By default, the threshold for detecting errored frame seconds on an interface is 1.
Step 5 Run:
efm error-frame-second notification enable
The interface is enabled to detect errored frame seconds.
By default, an interface cannot detect errored frame seconds.
----End

8.3.5 Checking the Configuration

By viewing EFM OAM configurations, you can check whether the configurations are successful.
Prerequisite
The configurations of the EFM OAM link monitoring function are complete.
Procedure
l
l
----End
Example
Run the
interface. For example:
Issue 02 (2011-09-10)
interface-type interface-number
Run the
display efm
{ all | interface interface-type interface-number } command to check
information about EFM OAM on an interface.
Run the
display efm session
to check the status of the EFM OAM protocol on an interface.
display efm
command. You can view information about link monitoring on the
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
period
threshold
{ all | interface interface-type interface-number } command
8 Ethernet OAM Configuration
397

Advertisement

Table of Contents
loading

This manual is also suitable for:

Netengine40e

Table of Contents