Data Preparation
To configure EFM OAM link monitoring, you need the following data.
No.
1
2
3

8.3.2 (Optional) Detecting Errored Frames of EFM OAM

When an interface is enabled to detect errored frames, the NE80E/40E generates an errored
frame event and notifies the peer, if the number of errored frames reaches or exceeds the
threshold within a set period.
Context
Do as follows on the devices at one end or both ends of the link:
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
interface
The interface view of an interface at one end of the link is displayed.
Step 3 Run:
efm error-frame period
The period for detecting errored frames on the interface is set.
By default, the period for detecting errored frames on an interface is 1 second.
Step 4 Run:
efm error-frame threshold
The threshold for detecting errored frames on the interface is set.
By default, the threshold for detecting errored frames on an interface is 1.
Step 5 Run:
efm error-frame notification enable
The interface is enabled to detect errored frames.
Issue 02 (2011-09-10)
Configuring EFM OAM
Data
(Optional) Period and threshold for detecting errored frames of EFM OAM
(Optional) Period and threshold for detecting errored codes of EFM OAM
(Optional) Period and threshold for detecting errored frame seconds of EFM OAM
interface-type interface-number
period
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
threshold