Example For Configuring Single-Hop Bfd6 For A Layer 3 Physical Link - Huawei NetEngine80E Configuration Manual - Reliability

Hide thumbs Also See for NetEngine80E:
Table of Contents

Advertisement

HUAWEI NetEngine80E/40E Router
Configuration Guide - Reliability
l
5.16.15 Example for Configuring Single-hop BFD6 for a Layer 3
Physical Link
This example describes how to configure single-hop BFD6 for a Layer 3 physical link to monitor
and rapidly detect faults in the IPv6 link between two directly-connected devices.
Networking Requirements
On the network shown in
direct link between Router A and Router C.
Figure 5-18 Networking diagram of single-hop BFD6 for a Layer 3 physical link
RouterA
Configuration Roadmap
The configuration roadmap is as follows:
1.
2.
Issue 02 (2011-09-10)
#
interface GigabitEthernet1/0/0
undo shutdown
port vlan-stacking vlan 10 stack-vlan 100
#
interface GigabitEthernet1/0/1
undo shutdown
port trunk allow-pass vlan 100
#
interface GigabitEthernet1/0/2
undo shutdown
port trunk allow-pass vlan 100
#
return
Configuration file of Switch 2
#
sysname Switch2
#
vlan batch 10
#
interface GigabitEthernet2/0/0
undo shutdown
port default vlan 10
#
interface GigabitEthernet1/0/0
undo shutdown
port trunk allow-pass vlan 10
#
return
Figure
GE1/0/0
2001::1/64
Configure a BFD6 session on Router A to detect faults in the directly connected link from
Router A to Router B.
Configure a BFD6 session on Router B to detect faults in the directly connected link from
Router B to Router A.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
5-18, BFD in asynchronous mode is set to detect faults in the