8.14 Associating Ethernet CFM with VPLS (by Using Sub-
interfaces for QinQ VLAN Tag Termination)
In the scenario where PEs that send packets with double VLAN tags access a Virtual Private
LAN Service (VPLS) network, you can configure sub-interfaces for QinQ VLAN tag
termination on AC interfaces of the PEs to bind VSIs and then configure Ethernet CFM on the
PEs.

8.14.1 Establishing the Configuration Task

Before associating Ethernet CFM with VPLS, you must check whether packets received on PEs
carry one VLAN tag or double VLAN tags. If PEs receive packets with one VLAN tag, PEs can
access a VPLS network through common sub-interfaces. If PEs receive packets with double
VLAN tags, you must bind sub-interfaces for QinQ VLAN tag termination to VSIs. The
following describes the configuration in the scenario where PEs receive packets with double
VLAN tags.
Applicable Environment
As shown in
l
l
l
l
MEPs within the same MA can detect the connectivity between themselves by exchanging
CCMs. Once a connectivity fault is detected, you can perform the MAC ping or MAC trace
operation to further locate the fault.
Figure 8-14 Networking diagram of associating Ethernet CFM with VPLS
Issue 02 (2011-09-10)
Figure
8-14, MAs are configured between:
PEs
Switches and local PEs
Switches and remote PEs
Switches
Switch1
CE1
user
network1
802.1ag
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
PE1
PE2
VPLS
802.1ag
802.1ag
802.1ag
8 Ethernet OAM Configuration
CE2
Switch2
user
network2
802.1ag
MEP
MIP
446