Checking The Configuration - Huawei NetEngine80E Configuration Manual - Reliability

Hide thumbs Also See for NetEngine80E:
Table of Contents

Advertisement

HUAWEI NetEngine80E/40E Router
Configuration Guide - Reliability
The procedure for configuring one-way and two-way DM is as follows:
All the steps must be performed on the MEP and RMEP unless otherwise specified.
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
mpls-tp meg
The MEG view is displayed.
Step 3 Choose one of the following sub-procedures as needed:
l Configure one-way packet delay measurement.
l Configure two-way DM.
----End

10.3.7 Checking the Configuration

After MPLS-TP OAM functions are configured for a PW, performance statistics and fault
detection information can be queried.
Prerequisite
All configurations of MPLS-TP OAM functions for a PW are complete.
Procedure
l
l
l
Issue 02 (2011-09-10)
NOTE
meg-name
Run the
delay-measure one-way
*
value ]
command to enable one-way DM.
Run the following commands to query the one-way DM results in different situations:
– If the
delay-measure one-way
the direction from the source end to the destination end. To view packet delay
measurement results, you must run the
type delay-measure one-way command on the RMEP.
– If the
delay-measure one-way
direction from the destination end to the source end. To view delay measurement results,
you can run the
display mpls-tp oam
one-way command on the local MEP.
Run the
delay-measure two-way
value |two-time-stamp ]
Run the
display mpls-tp oam ais
Run the
display mpls-tp oam current-alarm
a MEG.
Run the
display mpls-tp oam me
remote-mep-id ] ] command to check ME information about the MEG.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
[ interval interval-value | count count-value | exp exp-
command is run on the local MEP, DM is performed in
display mpls-tp oam
command is run on the RMEP, DM is performed in the
meg meg-name statistic-type delay-measure
[ interval interval-value | count count-value | exp exp-
*
command to enable two-way DM.
command to check the AIS configuration on a device.
command to check alarm information about
meg meg-name [ mep-id mep-id [ remote-mep-id
10 MPLS-TP OAM Configuration
meg meg-name statistic-
684