Configuration Guide - Reliability
Step 8 Verify the configuration.
After the preceding configuration, run the display cfm mep command and the display cfm
remote-mep command on PE1, PE2, and PE3. You can view that the configuration of Ethernet
CFM succeeds. Ethernet CFM can fast detect faults between PEs of VSIs and notify the NMS.
Take PE1 as an example.
[PE1] display cfm mep md md1
The total number of MEPs is 2
MD Name
MD Name Format
Level
MA Name
MA Name Format
MEP ID
Vlan ID
VSI Name
Interface Name
CCM Send
Direction
MD Name
MD Name Format
Level
MA Name
MA Name Format
MEP ID
Vlan ID
VSI Name
Interface Name
CCM Send
Direction
[PE1] display cfm remote-mep md md1
The total number of RMEPs is 2
The status of RMEPS : 2 up, 0 down
--------------------------------------------------
MD Name
Level
MA Name
RMEP ID
Vlan ID
VSI Name
MAC
CCM Receive
Trigger-If-Down
CFM Status
MD Name
Level
MA Name
RMEP ID
Vlan ID
VSI Name
MAC
CCM Receive
Trigger-If-Down
CFM Status
----End
Configuration Files
l
Issue 02 (2011-09-10)
: md1
: string
: 0
: ma1
: string
: 2
: --
: --
: GigabitEthernet1/0/1.1
: enabled
: inward
: md1
: string
: 0
: ma1
: string
: 3
: --
: --
: GigabitEthernet1/0/1.1
: enabled
: inward
: md1
: 0
: ma1
: 2
: --
: --
: --
: enabled
: disabled
: up
: md1
: 0
: ma1
: 3
: --
: --
: --
: enabled
: disabled
: up
Configuration file of PE1
#
sysname PE1
#
cfm enable
#
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.