The MA view is displayed.
Step 4 Run:
alarm occur time
The anti-jitter time during alarm generation is configured.
----End

8.8 Fault Verification on the Ethernet

By sending detection packets and waiting for replies, you can test connectivity of the path
between devices.

8.8.1 Establishing the Configuration Task

Before configuring the Ethernet fault verification function, familiarize yourself with the
applicable environment, complete the pre-configuration tasks, and obtain the required data. This
can help you complete the configuration task quickly and accurately.
Applicable Environment
To manually detect the connectivity between two devices, you can send test packets and wait
for a reply to test whether the destination device is reachable. There are the following scenarios
based on the type of the link to be tested:
l
l
l
Pre-configuration Tasks
Before implementing 802.1ag MAC ping, complete the following tasks:
l
No pre-configuration tasks are needed to implement Gmac ping and PBB-TE MAC ping.
Data Preparation
To detect the connectivity on the Ethernet, you need the following data.
No.
1
2
3
Issue 02 (2011-09-10)
time
For the network where the MD, MA, and MEP are configured, you can implement 802.1ag
MAC ping to test the connectivity between MEPs at the same maintenance level or between
MEPs and MIPs at the same maintenance level.
For the network where the MD, MA, and MEP are not configured, you can implement
Gmac ping to test the connectivity between two devices.
You can implement PBB-TE MAC ping to test the connectivity on the PBB-TE tunnel.
Configuring Ethernet CFM
Data
(Optional) Bridge MAC address of the device on which the destination MEP resides
or ID of the destination MEP
(Optional) Bridge MAC address of the device on which the destination MIP resides
(Optional) Number, size, timeout period, and outbound interface of LBMs
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
8 Ethernet OAM Configuration
422

Advertisement

Table of Contents
loading

This manual is also suitable for:

Netengine40e

Table of Contents