8.2.4 (Optional) Setting the Maximum Size of an EFM OAMPDU

You can configure the largest size of EFM OAMPDUs. On the current interface, the EFM
OAMPDUs whose sizes exceed the set size are regarded as illegal and thus discarded.
Context
Do as follows on the devices at both ends of the link:
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
interface
The interface view of an interface at one end of the link is displayed.
Step 3 Run:
efm packet max-size
The maximum size of an EFM OAMPDU is set.
By default, the maximum size of an EFM OAMPDU on an interface is 128 bytes.
If the maximum size of an EFM OAMPDU on both interfaces of the link is configured
differently, the two interfaces negotiate and determine the value during the OAM discovery
process. The smaller maximum size of an EFM OAMPDU set on the local interface and the peer
is selected.
----End
8.2.5 (Optional) Setting the Timeout Period for Waiting for OAM
PDUs
To change the time required for link connectivity detection, you can set the timeout period for
waiting for OAM PDUs.
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
interface
The view of the interface on one end of a link is displayed.
Step 3 Run:
efm timeout
The timeout period for waiting for OAM PDUs is set.
Issue 02 (2011-09-10)
interface-type interface-number
size
interface-type interface-number
timeout-value
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.