Data Preparation
To complete the configuration, you need the following data:
l
l
l
Procedure
Step 1 Set up a PW over a bidirectional LSP.
For details about how to set up a PW (between LSRs) based on a bidirectional LSP, see see
"Configuring a PW" in the HUAWEI NetEngine80E/40E Router Configuration Guide-MPLS
or information in the configuration files of this configuration example.
Step 2 Create an ME and bind it to a PW.
# Create an ME named test on PE1 and bind the ME to the PW.
<HUAWEI> system-view
[HUAWEI] sysname PE1
[PE1] mpls-tp meg test
[PE1-mpls-tp-meg-test] me l2vc peer-ip 3.3.3.3 vc-id 30000 vc-type vlan mep-id 1
remote-mep-id 2
# Create an ME named test on PE3 and bind the ME to the PW.
<HUAWEI> system-view
[HUAWEI] sysname PE3
[PE3] mpls-tp meg test
[PE3-mpls-tp-meg-test] me l2vc peer-ip 1.1.1.1 vc-id 30000 vc-type vlan mep-id 2
remote-mep-id 1
Step 3 Enable CC on the MEP and RMEP.
# Enable CC on PE1.
[PE1-mpls-tp-meg-test] cc send enable
[PE1-mpls-tp-meg-test] cc receive enable
# Enable CC on PE3.
[PE3-mpls-tp-meg-test] cc send enable
[PE3-mpls-tp-meg-test] cc receive enable
Step 4 Configure an alarm threshold for packet loss measurement.
# Configure an alarm threshold for packet loss measurement on PE1.
[PE1-mpls-tp-meg-test] lost-measure dual-ended loss-ratio threshold1 50
# Configure an alarm threshold for packet loss measurement on PE3.
[PE3-mpls-tp-meg-test] lost-measure dual-ended loss-ratio threshold1 50
Step 5 Enable dual-ended LM.
# Enable dual-ended LM on PE1.
[PE1-mpls-tp-meg-test] lost-measure dual-ended enable
[PE1-mpls-tp-meg-test] return
# Enable dual-ended LM on PE3.
[PE3-mpls-tp-meg-test] lost-measure dual-ended enable
[PE3-mpls-tp-meg-test] return
Step 6 Verify the configuration.
Run the display mpls-tp oam command on PE1 to view statistics about packet loss ratios.
Issue 02 (2011-09-10)
MEG name
ID of the VC bound to the ME
Alarm threshold for packet loss measurement
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.