Example For Associating Ethernet Cfm With An Interface - Huawei NetEngine80E Configuration Manual - Reliability

Hide thumbs Also See for NetEngine80E:
Table of Contents

Advertisement

HUAWEI NetEngine80E/40E Router
Configuration Guide - Reliability
l

8.18.5 Example for Associating Ethernet CFM with an Interface

In this example, by associating Ethernet CFM with an interface, you can detect a fault on the
link between a CE and a UPE through LACP.
Networking Requirements
As shown in
Router B. Router A acts as the CE device. Router B acts as the UPE device. It is required that
the following be achieved:
l
l
Issue 02 (2011-09-10)
mep ccm-send mep-id 2 enable
remote-mep mep-id 1
remote-mep ccm-receive mep-id 1 enable
#
return
Configuration file of Router F
#
sysname RouterF
#
vlan batch 2
#
cfm version standard
cfm enable
#
interface GigabitEthernet1/0/1
undo shutdown
portswitch
port trunk allow-pass vlan 2
#
interface GigabitEthernet1/0/3
undo shutdown
portswitch
port trunk allow-pass vlan 2
#
cfm md md1 level 6
ma ma1
map vlan 2
mep mep-id 1 interface gigabitethernet 1/0/1 inward
mep ccm-send mep-id 1 enable
remote-mep mep-id 2
remote-mep ccm-receive mep-id 2 enable
#
return
Figure
8-20, a user network is connected to an ISP network through Router A and
The bandwidth for the user network to access the ISP network is 2000 Mbit/s and an inactive
link that serves as a backup is provided.
When the active link between the user network and the ISP network fails, the LACP module
on the interface can sense the fault within 50 ms and stop forwarding data on the active
link.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
8 Ethernet OAM Configuration
478