Procedure
Step 1 Assign IP addresses to the interfaces directly connecting Router A and Router B.
# Assign an IP address to the interface on Router A.
<HUAWEI> system-view
[HUAWEI] sysname RouterA
[RouterA] interface gigabitethernet
[RouterA-GigabitEthernet1/0/0] undo shutdown
[RouterA-GigabitEthernet1/0/0] ip address 10.1.1.1 24
[RouterA-GigabitEthernet1/0/0] quit
# Assign an IP address to the interface on Router B.
<HUAWEI> system-view
[HUAWEI] sysname RouterB
[RouterB] interface gigabitethernet 1/0/0
[RouterB-GigabitEthernet1/0/0] undo shutdown
[RouterB-GigabitEthernet1/0/0] ip address 10.1.1.2 24
[RouterB-GigabitEthernet1/0/0] quit
Step 2 Configure a BFD session with the one-arm Echo function.
# Configure Router A.
[RouterA] bfd
[RouterA-bfd] quit
[RouterA] bfd atob bind peer-ip 10.1.1.2 interface gigabitEthernet1/0/0 one-arm-
echo
[RouterA-bfd-session-atob] discriminator local 1
[RouterA-bfd-session-atob] min-echo-rx-interval 100
[RouterA-bfd-session-atob] commit
[RouterA-bfd-session-atob] quit
Step 3 Verify the configuration.
After the preceding configurations are complete, run the display bfd session all verbose
command on Router A. You can see that a single-hop BFD session has been created and its status
is Up.
<RouterA> display bfd session all verbose
--------------------------------------------------------------------------------
Session MIndex : 256
--------------------------------------------------------------------------------
Local Discriminator
Session Detect Mode
BFD Bind Type
Bind Session Type
Bind Peer IP Address
NextHop Ip Address
Bind Interface
FSM Board Id
Echo Rx Interval (ms)
Actual Tx Interval (ms): 1000
Local Detect Multi
Echo Passive
Destination Port
Proc Interface Status
WTR Interval (ms)
Active Multi
Last Local Diagnostic
Issue 02 (2011-09-10)
Peer IP address to which a BFD session with the one-arm Echo function is bound
Local discriminator of a BFD session with the one-arm Echo function
The minimum interval between the receipt of BFD packets
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
1/0/0
(One Hop) State : Up
: 1
Remote Discriminator
:
Asynchronous One-arm-echo Mode
: Interface(gigabitEthernet1/0/0)
: Static
: 10.1.1.2
: 10.1.1.2
: EigabitEthernet1/0/0
: 0
TOS-EXP
: 100
Actual Rx Interval (ms): 1000
: 3
Detect Interval (ms)
: Disable
Acl Number
: 3784
TTL
: Disable
Process PST
: -
Local Demand Mode
: 3
: Control Detection Time Expired
5 BFD Configuration
Name : atob
: -
: 7
: 3000
: -
: 255
: Disable
: Disable
326