Huawei NetEngine80E Configuration Manual - Reliability page 500

Hide thumbs Also See for NetEngine80E:
Table of Contents

Advertisement

HUAWEI NetEngine80E/40E Router
Configuration Guide - Reliability
CCM Receive
Trigger-If-Down
CFM Status
----End
Configuration Files
l
l
Issue 02 (2011-09-10)
: enabled
: enabled
: up
Configuration file of Router A
#
sysname RouterA
#
cfm enable
#
interface Eth-Trunk2
portswitch
mode lacp-static
#
interface GigabitEthernet1/0/1
eth-trunk 2
cfm md md1 ma ma1 remote-mep mep-id 1 trigger if-down
#
interface GigabitEthernet1/0/2
eth-trunk 2
cfm md md1 ma ma2 remote-mep mep-id 3 trigger if-down
#
interface GigabitEthernet1/0/3
eth-trunk 2
cfm md md1 ma ma3 remote-mep mep-id 5 trigger if-down
#
cfm md md1
ma ma1
ccm-interval 10
mep mep-id 2 interface GigabitEthernet1/0/1 outward
mep ccm-send mep-id 2 enable
remote-mep mep-id 1
remote-mep ccm-receive mep-id 1 enable
ma ma2
ccm-interval 10
mep mep-id 4 interface GigabitEthernet1/0/2 outward
mep ccm-send mep-id 4 enable
remote-mep mep-id 3
remote-mep ccm-receive mep-id 3 enable
ma ma3
ccm-interval 10
mep mep-id 6 interface GigabitEthernet1/0/3 outward
mep ccm-send mep-id 6 enable
remote-mep mep-id 5
remote-mep ccm-receive mep-id 5 enable
#
return
Configuration file of Router B
#
sysname RouterB
#
lacp priority 100
#
cfm enable
#
interface Eth-Trunk2
portswitch
mode lacp-static
max bandwidth-affected-linknumber 2
#
interface GigabitEthernet1/0/1
eth-trunk 2
lacp priority
2000
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.