Associating Efm Oam With Ethernet Cfm; Establishing The Configuration Task - Huawei NetEngine80E Configuration Manual - Reliability

Hide thumbs Also See for NetEngine80E:
Table of Contents

Advertisement

HUAWEI NetEngine80E/40E Router
Configuration Guide - Reliability
Example
Run the
displayed as "enable", it means that the configuration succeeds.
<HUAWEI> display cfm remote-mep
The total number of RMEPs is : 1
The status of RMEPS : 0 up, 1 down, 0 disable
--------------------------------------------------
MD Name
Level
MA Name
RMEP ID
Vlan ID
VSI Name
L2VC ID
MAC
CCM Receive
Trigger-If-Down
CFM Status
Alarm Status

8.11 Associating EFM OAM with Ethernet CFM

By configuring the association between EFM OAM and Ethernet CFM, you can implement the
bidirectional fault notification.

8.11.1 Establishing the Configuration Task

Before configuring the association between EFM OAM and Ethernet CFM, familiarize yourself
with the applicable environment, complete the pre-configuration tasks, and obtain the required
data. This can help you complete the configuration task quickly and accurately.
Applicable Environment
IEEE 802.3ah is designed for the last mile of the Ethernet to detect the direct link between a CE
and a PE. IEEE 802.1ag is designed for a group of services or some specific network devices to
detect faults on the network. It functions between the following devices:
l
l
l
As shown in
CE2 and PE2; Ethernet CFM runs between PE1 and PE2. Configure the association between
Ethernet OAMs. When a fault occurs on the link between CE1 and PE1, Ethernet CFM sends
alarms of the fault to CE2.
Figure 8-11 Diagram of associating Ethernet OAM with Ethernet OAM
CE1
Issue 02 (2011-09-10)
display cfm remote-mep
: md110
: 0
: ma110
: 2
: --
: --
: 110 tagged
: 0025-9eb1-bce6
: enabled
: disabled
: down
: RemoteAlarm
CE and CE
PE and PE
CE and PE
Figure
8-11, EFM OAM or Ethernet CFM runs between CE1 and PE1, and between
PE1
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
command. If the "Trigger If-down" field for the RMEP is
PE2
CE2