Function
Pre-configuration Tasks
Before configuring MPLS-TP OAM for a PW, complete the following tasks:
l
l
Data Preparation
To configure MPLS-TP OAM for a PW, you need the following data.
No.
1
2
3
4
4
5

10.3.2 Creating an ME and Binding It to a PW

This section describes how to create an ME and bind it to a single-segment or multi-segment
PWE3 PW.
Context
If a transport path is a PW built over a bidirectional LSP, an ME created for the path must be
bound to the PW before MPLS-TP OAM is configured.
Perform the following steps on the MEP and RMEP:
Procedure
Step 1 Run:
Issue 02 (2011-09-10)
Application
Scenario
Delay and delay
jitter measurement
Setting up a PW based on a bidirectional LSP
Enabling the packet measurement function on the access circuit (AC) interface of the LSP.
Data
MEG name
ID of the VC bound to the ME
(Optional) Interval of Continuity Check Message (CCM) transmissions and priority
of CCMs
(Optional) Interval and number of loss measurement message (LMM) transmissions
and priority of LMMs
(Optional) Interval and number of transmissions of delay measurement packets and
priority of the packets
(Optional) Interval between AIS PDU transmissions and priority of AIS PDUs
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
10 MPLS-TP OAM Configuration
Configuration Procedure
Delay measurement
(DM): collects
statistics about delay and delay jitters
between the T-PEs of a PW built over a
bidirectional LSP.
677