Binding An Ma To A Vpls Network; Configuring Dm Frame Reception On A Remote Device - Huawei NetEngine80E Configuration Manual - Reliability

Hide thumbs Also See for NetEngine80E:
Table of Contents

Advertisement

HUAWEI NetEngine80E/40E Router
Configuration Guide - Reliability
No.
1
2
3
4

9.8.2 Binding an MA to a VPLS Network

Binding an MA to a VPLS network is a prerequisite for configuring single-ended frame loss
measurement, dual-ended frame loss measurement, one-way frame delay measurement, or two-
way frame delay measurement on the VPLS network.
Context
VPLS-based performance monitoring function is VSI-specific. Therefore, when deploying Y.
1731, bind an MA to a specified VSI, and then collect performance statistics of the MA. Then,
performance statistics about a specified PW or AC will be available.
l
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
cfm md
The MD view is displayed.
Step 3 Run:
ma
The MA view is displayed.
Step 4 Run:
map
The MA is bound to a VSI.
----End

9.8.3 Configuring DM Frame Reception on a Remote Device

When one-way frame delay measurement is configured for a link, DM frame reception needs to
be configured on a remote device.
Issue 02 (2011-09-10)
Data
Names of an MD and an MA
ID and type of a MEP and name of the interface where the MEP is located
Name of the VSI bound to an MA
ID of a remote MEP and MAC address of the interface where the remote MEP is
located
To make single-ended frame loss measurement on a PW between PEs on a VPLS network,
do as follows on the PEs:
md-name
ma-name
vsi vsi-name
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
9 Y.1731 Configuration
594