Edge-Core ECS4810-12M Layer 2 Management Manual page 797

Hide thumbs Also See for ECS4810-12M Layer 2:
Table of Contents

Advertisement

This example shows how to modify the sFlow port number for an already
configured collector.
Console(config)#sflow owner stat_server1 timeout 100 port 35100
Console(config)#
This command enables an sFlow polling data source, for a specified
sflow polling
interface, that polls periodically based on a specified time interval. Use the
instance
no form to remove the polling data source instance from the switch's sFlow
configuration.
S
YNTAX
sflow polling {interface interface} instance instance-id
no sflow polling {interface interface} instance instance-id
D
EFAULT
No sFlow polling instance is configured.
C
OMMAND
Privileged Exec
C
OMMAND
This command enables a polling data source and configures the interval at
which counter values are added to the sample datagram.
E
XAMPLE
This example sets the polling interval to 10 seconds.
Console(config)#interface ethernet 1/9
Console(config-if)#sflow polling-interval 10
Console(config-if)#
receiver owner-name polling-interval seconds
interface - The source from which the samples will be taken at
specified intervals and sent to a collector.
ethernet unit/port
unit - Stack unit. (Range: 1)
port - Port number. (Range: 1-12)
instance-id - An instance ID used to identify the sampling source.
(Range: 1)
owner-name - The associated receiver, to which the samples will be
sent. (Range: 1-30 alphanumeric characters)
polling-interval - The time interval at which the sFlow process
adds counter values to the sample datagram. (Range: 0-10000000
seconds, 0 disables this feature)
S
ETTING
M
ODE
U
SAGE
– 797 –
| Flow Sampling Commands
C
23
HAPTER

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ecs4810-12m

Table of Contents