Uni Directional Link Detection Commands; Udld Message-Interval; Table 123: Unidirectional Link Detection Commands - Edge-Core ECS4810-12M Layer 2 Management Manual

Hide thumbs Also See for ECS4810-12M Layer 2:
Table of Contents

Advertisement

32
udld
message-interval
U
D
NI
IRECTIONAL
C
OMMANDS
The switch can be configured to detect and disable unidirectional Ethernet
fiber or copper links. When enabled, the protocol advertises a port's
identity and learns about its neighbors on a specific LAN segment; and
stores information about its neighbors in a cache. It can also send out a
train of echo messages under circumstances that require fast notifications
or re-synchronization of the cached information.

Table 123: UniDirectional Link Detection Commands

Command
Function

udld message-interval

Configures the message interval between UDLD
probe messages
udld aggressive
Sets UDLD to aggressive mode on an interface
udld port
Enables UDLD on an interface
show udld
Shows UDLD configuration settings and
operational status
This command configures the message interval between UDLD probe
messages for ports in advertisement phase and determined to be
bidirectional. Use the no form to restore the default setting.
S
YNTAX
udld message-interval message-interval
no message-interval
message-interval – The interval at which a port sends UDLD probe
messages after linkup or detection phases. (Range: 7-90 seconds)
D
S
EFAULT
ETTING
15 seconds
C
M
OMMAND
ODE
Global Configuration
C
U
OMMAND
SAGE
During the detection phase, messages are exchanged at the maximum
rate of one per second. After that, if the protocol reaches a stable state and
determines that the link is bidirectional, the message interval is increased
to a configurable value based on a curve known as M1(t), a time-based
function described in RFC 5171.
– 1027 –
L
D
INK
ETECTION
Mode
GC
IC
IC
PE

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ecs4810-12m

Table of Contents