Table 24: Logging Levels - Edge-Core ECS4810-12M Layer 2 Management Manual

Hide thumbs Also See for ECS4810-12M Layer 2:
Table of Contents

Advertisement

| Basic Administration Protocols
C
14
HAPTER
Configuring Event Logging
Severe error messages that are logged to flash memory are permanently
stored in the switch to assist in troubleshooting network problems. Up to
4096 log entries can be stored in the flash memory, with the oldest entries
being overwritten first when the available log memory (256 kilobytes) has
been exceeded.
The System Logs page allows you to configure and limit system messages
that are logged to flash or RAM memory. The default is for event levels 0 to
3 to be logged to flash and levels 0 to 7 to be logged to RAM.
CLI R
EFERENCES
"Event Logging" on page 726
P
ARAMETERS
These parameters are displayed:
System Log Status – Enables/disables the logging of debug or error
messages to the logging process. (Default: Enabled)
Flash Level – Limits log messages saved to the switch's permanent
flash memory for all levels up to the specified level. For example, if
level 3 is specified, all messages from level 0 to level 3 will be logged to
flash. (Range: 0-7, Default: 3)

Table 24: Logging Levels

Level
Severity Name
7
Debug
6
Informational
5
Notice
4
Warning
3
Error
2
Critical
1
Alert
0
Emergency
* There are only Level 2, 5 and 6 error messages for the current firmware release.
RAM Level – Limits log messages saved to the switch's temporary RAM
memory for all levels up to the specified level. For example, if level 7 is
specified, all messages from level 0 to level 7 will be logged to RAM.
(Range: 0-7, Default: 7)
The Flash Level must be equal to or less than the RAM Level.
N
:
OTE
All log messages are retained in RAM and Flash after a warm restart
N
:
OTE
(i.e., power is reset through the command interface).
– 418 –
Description
Debugging messages
Informational messages only
Normal but significant condition, such as cold
start
Warning conditions (e.g., return false,
unexpected return)
Error conditions (e.g., invalid input, default used)
Critical conditions (e.g., memory allocation, or
free memory error - resource exhausted)
Immediate action needed
System unusable

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ecs4810-12m

Table of Contents