Transceiver-Threshold Temperature - Edge-Core ECS4810-12M Layer 2 Management Manual

Hide thumbs Also See for ECS4810-12M Layer 2:
Table of Contents

Advertisement

| Interface Commands
C
27
HAPTER
Transceiver Threshold Configuration
transceiver-
threshold
temperature
C
U
OMMAND
SAGE
The threshold value is the power ratio in decibels (dB) of the measured
power referenced to one milliwatt (mW).
Refer to the Command Usage section under the
current
command for more information on configuring transceiver
thresholds.
Trap messages enabled by the
to any management station configured by the
command.
E
XAMPLE
The following example sets alarm thresholds for the signal power received
at port 1.
Console(config)interface ethernet 1/1
Console(config-if)#transceiver-threshold rx-power low-alarm -21
Console(config-if)#transceiver-threshold rx-power high-alarm -3
Console#
This command sets thresholds for the transceiver temperature which can
be used to trigger an alarm or warning message. Use the no form to
restore the default settings.
S
YNTAX
transceiver-threshold temperature {high-alarm | high-warning
| low-alarm | low-warning} threshold-value
no transceiver-threshold temperature
high-alarm – Sets the high temperature threshold for an alarm
message.
high-warning – Sets the high temperature threshold for a warning
message.
low-alarm – Sets the low temperature threshold for an alarm
message.
low-warning – Sets the low temperature threshold for a warning
message.
threshold-value – The threshold of the transceiver temperature.
(Range: -20000 - 20000 in units of 0.01 Celsius)
D
S
EFAULT
ETTING
°
High Alarm: 75.00
C
°
HIgh Warning: 70.00
C
°
Low Alarm: -123.00
C
°
Low Warning: 0.00
C
– 970 –
transceiver-threshold
transceiver-monitor
command are sent
snmp-server host