Adjusting The Dip Switch Settings; Connecting The Terminal Block For Supply Voltage And Signal Contact - Hirschmann RS20 Series User Manual

Hide thumbs Also See for RS20 Series:
Table of Contents

Advertisement

2.1.3

Adjusting the DIP switch settings

The 2-pin DIP switch on the front panel of the device offers you the following
possibilities:
RM
Stand by
switch
switch
OFF
OFF
ON
OFF
OFF
ON
ON
ON
Fig. 9:
2-pin DIP switch
V Check whether the switch default settings match your requirements
before starting the device.
2.1.4
Connecting the terminal block for supply voltage and
signal contact
The supply voltage and the signal contacts are connected via a 6-pin terminal
block with snap locking.
Supply voltage
U
The supply voltage can be connected redundantly. Both inputs are
uncoupled. With redundant supply, the transformer supplies the device
alone with the higher output voltage. The supply voltage is electrically
isolated from the housing.
You can choose between DC or AC voltage when connecting the supply
voltage. You use the +24V and 0V pins to connect the AC voltage
Fig. 10).
.
+24V(P1)
+
9,6...60 VDC
DC voltage
Fig. 10:
Connection of the supply voltage on the 6-pin terminal block
RS20/RS30
Release 2.0 03/06
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Ring
Ring
redun-
coupling
dancy
on
off
on
off
on
on
off
off
RM
Stand by
FAULT
0V 0V
+24V(P2)
-
-
+
9,6...60 VDC
Redun-
dancy
Ring port
Manager
off
1 + 2
on
1 + 2
off
1 + 2
off
ON
FAULT
+24V(P1)
0V 0V
+24V(P2)
G
G
18...30 VAC
18...30 VAC
AC voltage
Control
Coupling
port
port