Honda C8R600F4 Service Manual page 310

Table of Contents

Advertisement

CHARGING SYSTEM
Be sure that the
Start the engine and warm it up to the operating
battery
is
in good
temperature; stop the engine.
condition before
Connect the multimeter between the positive and
performing this
negative terminals of the battery.
test.
CAUTION:
• To prevem shon, make abso/urely cenafn which
are the positive and negative terminals or cable.
• Do not disconnect the battery or any cable in the
charging system without first switching off the
ignition switch. Failure to follow this precaution
can damage the tester or electrical components.
With the headlight on Hi beam, restart the engine.
Measure the voltage on the multitester when the
engine runs at 5,000 rpm.
STANDARD:
Measured battery voltage (page 16-4) <Measured
charaina volfa!JA (sAA ahovA)< 155 V
ALTERNATOR CHARGING COIL
INSPECTION
Remove the left side fairing (page 2-4).
Disconnect the alternator 3P (white) connector.
Measure the resistance between the wire terminals
of the alternator side connector.
STANDARD: 0.1-1.0
Q
(20 °C/ 68 °F)
Check for continuity between each wire terminal of
the alternator side connector and ground.
There should not be continuity.
Replace the alternator stator
if
resistance is out of
specification, or
if
any wire has continuity to
ground.
Refer to section 10 for alternator stator replace-
ment.